sd_varlink_send
systemd
sd_varlink_send
3
sd_varlink_send
sd_varlink_sendb
sd_varlink_sendbo
Enqueues a Varlink method call, not expecting a reply
#include <systemd/sd-varlink.h>
int
sd_varlink_send
sd_varlink *
link
const char *
method
sd_json_variant *
parameters
int
sd_varlink_sendb
sd_varlink *
link
const char *
method
…
int
sd_varlink_sendbo
sd_varlink *
link
const char *
method
…
Description
sd_varlink_send() submits a method call via a Varlink connection. It takes the Varlink connection object, a method name as string parameter, and a JSON object containing the parameters to pass as function parameters. This call is asynchronous: the message will not be delivered immediately but only once sd_varlink_process(3) is invoked (which will happen automatically in one of the following event loop iterations if the Varlink connection is attached to an even loop).
sd_varlink_sendb() is similar to sd_varlink_send(), but instead of expecting a fully constructed sd_json_variant object carrying the parameters, this object is constructed on-the-fly directly from the parameter list, in a style identical to sd_json_build(3).
sd_varlink_sendbo() is identical to sd_varlink_sendb(), but an enclosing object is implicitly added, so that the parameter list is expected to consist of field pairs only. For details about the expected argument list, see sd_json_buildo(3).
Use sd_varlink_send(), sd_varlink_sendb() and sd_varlink_sendbo() only if no method call results are required, as they neither provide return parameters nor success/failure information. Use sd_varlink_call(3) (and related calls) to submit a method call synchronously, returning the server's response.
Return Value
On success, sd_varlink_send(), sd_varlink_sendb() and sd_varlink_sendbo() return a non-negative integer. On failure, they return a negative errno-style error code.
Errors
Returned errors may indicate the following problems:
-EINVAL
An argument is invalid.
-ENOMEM
Memory allocation failed.
-ENOTCONN
The Varlink connection object is not connected.
-EBUSY
The Varlink connection object is already used for other purposes, i.e. executing a method call or similar.
-ENOBUFS
The internal limit of queued messages for the Varlink connection has been reached. This limit is set very high, and hitting it typically indicates that the Varlink connection object is stalled — possibly because sd_varlink_process() has not been called regularly enough, or because the peer is not processing any queued messages. This limit is a safety precaution to ensure a stalled peer will not result in unbounded memory allocations on the client side.
History
sd_varlink_send(), sd_varlink_sendb(), sd_varlink_sendbo() were added in version 257.
See Also
systemd(1), sd-varlink(3), sd_varlink_call(3), sd_varlink_build(3)
谢谢你的反馈!